  4. Influence of Particle Composition and Size on the Accuracy of Low Cost Pm Sensors: Findings from Field Campaigns
Details

Influence of Particle Composition and Size on the Accuracy of Low Cost Pm Sensors: Findings from Field Campaigns

Journal
Frontiers in Environmental Science
Date Issued
2021
Author(s)
Rubio-Campos, M  
Gramsch-Labra, E  
Perez-Jara, P  
Soto-Ormeno, C  
Moreno-Herrera, F  
DOI
https://doi.org/10.3389/fenvs.2021.751267
Abstract
In the last decade, many low-cost monitoring sensors and sensor-networks have been used as an alternative air quality assessment method. It is also well known that these low cost monitors have calibration, accuracy and long term variation problems which require various calibration techniques. In this work PM2.5 and PM10 low cost sensors (Plantower and Nova Fitness) have been tested in five cities under different environmental conditions and compared with collocated standard instruments. Simultaneously, particle composition (organic and black carbon, sulfate, nitrate, chloride, ammonium, and chemical elements) has been measured in the same places to study its influence on the accuracy. The results show a very large variability in the correlation between the low cost sensors and collocated standard instruments depending on the composition and size of particles present in the site. The PM10 correlation coefficient (R2) between the low cost sensor and a collocated regulatory instrument varied from to 0.95 in Temuco to 0.04 in Los Caleos. PM2.5 correlation varied from 0.97 to 0.68 in the same places. It was found that sites that had higher proportion of large particles had lower correlation between the low cost sensor and the regulatory instrument. Sites that had higher relative concentration of organic and black carbon had better correlation because these species are mostly below the 1 μm size range. Sites that had higher sulfate, nitrate or SiO2 concentrations in PM2.5 or PM10 had low correlation most likely because these particles have a scattering coefficients that depends on its size or composition, thus they can be classified incorrectly. Copyright © 2021 Gramsch, Oyola, Reyes, Vásquez, Rubio, Soto, Pérez, Moreno and Gutiérrez.
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Logo USACH

Universidad de Santiago de Chile
Avenida Libertador Bernardo O'Higgins nº 3363. Estación Central. Santiago Chile.
ciencia.abierta@usach.cl © 2023
The DSpace CRIS Project - Modificado por VRIIC USACH.

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Logo DSpace-CRIS
Repository logo COAR Notify