Repository logo
Log In(current)
  • Inicio
  • Personal de Investigación
  • Unidad Académica
  • Publicaciones
  • Colecciones
    Datos de Investigacion Divulgacion cientifica Personal de Investigacion Protecciones Proyectos Externos Proyectos Internos Publicaciones Tesis
  1. Home
  2. Universidad de Santiago de Chile
  3. Publicaciones ANID
  4. Gas Holdup Estimation Using Maxwell Equation in Flotation Systems: Revisited
Details

Gas Holdup Estimation Using Maxwell Equation in Flotation Systems: Revisited

Journal
Minerals Engineering
ISSN
0892-6875
Date Issued
2016
Author(s)
Magne-Ortega, L  
Maldonado-Saavedra, M  
DOI
https://doi.org/10.1016/j.mineng.2016.04.005
Abstract
Estimation of gas holdup from electrical conductivity measurements has been used in lab and industrial installations. The approach is based on the application of Maxwell s model, which relates the concentration of a dispersed phase in a continuous medium to measurements of the electrical conductivity of the dispersed phase, continuous medium and the resulting mixture (dispersion). When applied to inferring the collection zone gas holdup in a three phase system and to facilitate real-time on-line measurement, the slurry is assumed to behave as the continuous medium and gas bubbles as a non-conducting dispersed phase. This article derives an equation for estimating gas holdup in a three phase system, eliminating the assumption that the slurry behaves as a continuous medium but rather as a dispersion of non-conducting solid particles in water. In this formulation only water behaves as the continuous medium in the sense of Maxwell, and gas holdup in a three phase system is then calculated from the application of the Maxwell model twice: (1) to determine solid content in a two-phase system, and (2) to determine solid plus gas holdup in a three phase system. To validate the new equation and quantify the errors incurred by assuming slurry is the continuous phase a laboratory flotation cell was instrumented to continuously measure the conductivity of two and three phase dispersions with known solids contents. As the amount of gas in a lab flotation machine is difficult to measure directly or by another indirect technique such as using pressure signals, 2.5 mm dielectric plastic spheres having a density of ca. 1.3 g/cm3 were used instead of air bubbles for validation. Experimental results demonstrated that the continuous medium assumption underestimates gas holdup and that the resulting bias error increases linearly with the solid content and decreases with the magnitude of gas holdup. © 2016 Elsevier Ltd
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Logo USACH

Universidad de Santiago de Chile
Avenida Libertador Bernardo O'Higgins nº 3363. Estación Central. Santiago Chile.
ciencia.abierta@usach.cl © 2023
The DSpace CRIS Project - Modificado por VRIIC USACH.

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Logo DSpace-CRIS
Repository logo COAR Notify