Repository logo
Log In(current)
  • Inicio
  • Personal de Investigación
  • Unidad Académica
  • Publicaciones
  • Colecciones
    Datos de Investigacion Divulgacion cientifica Personal de Investigacion Protecciones Proyectos Externos Proyectos Internos Publicaciones Tesis
  1. Home
  2. Universidad de Santiago de Chile
  3. Publicaciones ANID
  4. Stripping Voltammetry Microprobe (Spv): Substantial Improvements of the Protocol
Details

Stripping Voltammetry Microprobe (Spv): Substantial Improvements of the Protocol

Journal
Journal of Electroanalytical Chemistry
ISSN
1572-6657
Date Issued
2015
Author(s)
Paez-Collio, M  
Paez-Collio, M  
Zagal-Moya, J  
Zagal-Moya, J  
Pavez-Irrazabal, J  
Pavez-Irrazabal, J  
Gulppi-Cabra, M  
Gulppi-Cabra, M  
Azocar-Guzman, M  
Azocar-Guzman, M  
DOI
https://doi.org/10.1016/j.jelechem.2015.03.008
Abstract
The recently introduced new electroanalytical protocol of stripping voltammetry microprobe (SPV) has been considerably improved with respect to analytical performance. The determination of the silver ions is shown to be possible by the precipitation of a solution of silver drops on an electrode surface, which is previously moistened with a solution of NaCl. The electrode thus modified, i.e., with the silver chloride precipitate on the surface, is introduced into a chloride electrolyte and is negatively polarized to reduce the silver salt to metallic silver. Whereas this reduction process produces only a broad signal, the following electrochemical oxidation of the silver metal back to AgCl provides a highly sensitive and narrow signal, which lends itself for analysis. The linear range for determination of silver ions following this protocol is 1.4 × 10-7 to 7.4 × 10-4 mol L-1 and the detection limit is 4.6 × 10-8 mol L-1. © 2015 Elsevier B.V. All rights reserved.
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Logo USACH

Universidad de Santiago de Chile
Avenida Libertador Bernardo O'Higgins nº 3363. Estación Central. Santiago Chile.
ciencia.abierta@usach.cl © 2023
The DSpace CRIS Project - Modificado por VRIIC USACH.

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Logo DSpace-CRIS
Repository logo COAR Notify