Repository logo
Log In(current)
  • Inicio
  • Personal de Investigación
  • Unidad Académica
  • Publicaciones
  • Colecciones
    Datos de Investigacion Divulgacion cientifica Personal de Investigacion Protecciones Proyectos Externos Proyectos Internos Publicaciones Tesis
  1. Home
  2. Universidad de Santiago de Chile
  3. Publicaciones ANID
  4. Multichannel Sensor for Detection of Molybdenum Ions Based on Nitrogen-Doped Carbon Quantum Dot Ensembles
Details

Multichannel Sensor for Detection of Molybdenum Ions Based on Nitrogen-Doped Carbon Quantum Dot Ensembles

Journal
C-Journal of Carbon Research
ISSN
2311-5629
Date Issued
2024
Author(s)
Melo-Freire, R  
DOI
https://doi.org/10.3390/c10030057
Abstract
Trace elements such as cobalt (Co), molybdenum (Mo), and zinc (Zn) play necessary roles in different biological functions. Co is a microelement that influences the vascular system. Mo works as an enzymatic cofactor of three enzymes (aldehyde oxidase, sulfite oxidase, and xanthine oxidase dehydrogenase). However, these elements are difficult to detect, since the analytical methods developed have a high cost, which restrict their applicability. In this sense, fluorescent sensors are an alternative for detecting trace elements, such as Mo4+ ions. Herein, a new multichannel trace elements sensor has been proposed to detect Mo entities. In this sense, two different N-CQDs were synthesized and fully characterized. The N-CQDs presented quantum yield values of 25.93% and 6.02% and excellent solubility in water. Also, a mixture of these two carbon-based nanoparticles was used to identify and to quantify Mo in water between seven different trace elements. The method was found to reach 1.28 and 3.88 ppm for limit of detection (LOD) and quantification (LOQ), respectively. To further verify the potential of the detection platform, the multichannel sensor was applied to identify the different concentrations of metal ions (Fe2+, Co2+, Mn2+, Cu2+, Zn2+, Mg2+, and Mo4+) in water. The data matrix was treated using different algorithms, such as K-Means and Discriminant Analysis (DA). The detection strategy has successfully identified the molybdenum ions at 5 ppm. This result shows the potential application of a multichannel sensor toward the detection of Mo entities, since it is comparable with the molybdenum test already available on the market. © 2024 by the authors.
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Logo USACH

Universidad de Santiago de Chile
Avenida Libertador Bernardo O'Higgins nº 3363. Estación Central. Santiago Chile.
ciencia.abierta@usach.cl © 2023
The DSpace CRIS Project - Modificado por VRIIC USACH.

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Logo DSpace-CRIS
Repository logo COAR Notify