  4. Assessment of Industrial Modules to Design a Gfma Process for Cyanide Recovery Based on a Phenomenological Model
Details

Assessment of Industrial Modules to Design a Gfma Process for Cyanide Recovery Based on a Phenomenological Model

Journal
Processes
ISSN
2227-9717
Date Issued
2018
Author(s)
Romero-Figueroa, J  
DOI
https://doi.org/10.3390/pr6040034
Abstract
Cyanide recovery in the gold-mining industry is a crucial step in terms of the cost of operation. Currently, a process such as AVR (acidification, volatilization and recycling), based on packed towers for stripping and absorption stages, addresses this issue with high levels of investment and operational costs. Gas-filled membrane absorption (GFMA) emerges then as an attractive alternative because the stripping and absorption stages can be performed in a single stage, reducing associated investment and operational costs. Despite the advantages of this technology, applications at industrial scale are still emerging. A possible reason is the lack of clear scaling-up methodologies where experimental data can be taken to select the optimum industrial hollow-fiber membrane contactor module (HFMC). The present study proposes a methodology to select adequately between available industrial Liqui-CelTM modules to design a process under optimal operational conditions. The methodology is based on a phenomenological model developed for recovering cyanide by using the GFMA process. Simulation of the Liqui-CelTM industrial membrane modules employed to recover cyanide in the GFMA process, both in a batch arrangement with a feed-flow rate, and in the range 10-125 m3/h, showed that in terms of cyanide recovery there are no differences between the modules tested when they work at the same feed-flow rate. The design criteria to scale-up was determined: to ensure performance at different scales, the length of the transfer unit (HTU) should be kept at different capacities of HFMC modules that comprise the equipment characteristics (mass-transfer area, stream velocities, and mass-transfer coefficient values). Additionally, the number of commercial modules Liqui-CelTM required to treat 57 m3/h and 250 m3/h ensuring a cyanide recovery of 95% was also determined. Finally, the most profitable option (lower pressure drop and module cost) resulted in the use of the 14 × 40 Liqui-CelTM module. © 2018 by the authors.
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Logo USACH

Universidad de Santiago de Chile
Avenida Libertador Bernardo O'Higgins nº 3363. Estación Central. Santiago Chile.
ciencia.abierta@usach.cl © 2023
The DSpace CRIS Project - Modificado por VRIIC USACH.

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Logo DSpace-CRIS
Repository logo COAR Notify